A headless run ends 1 when the daemon's connection stays down a minute, and the terminal UI is refused without a terminal

TUI decision 116 · accepted · 2026-09-26

D20 in docs/developer/defects.md, left over from the first-run and headless work. The client reconnects to a daemon on its own and never gives up, so troupe run --headless against a daemon that was stopped or crashed waited for ever on a rest that could not come. The printer now reads the connection as the status line does, from the worker's :remote_status: down starts a minute's clock (:reconnect_ms), up stops it, and a clock that runs out is a run that ended short, 1, with the reason as its last line. A minute outlasts a daemon restart and the reconnect backoff's 30-second ceiling. Plain troupe, troupe resume and troupe run without --headless, with standard output not a terminal (:io.getopts/1's stdout), drew into the file and never exited, since nothing could press the key that quits; they now say so in one line that names troupe run --headless and troupe config, and exit 1 before a session is made. A plane session's model key is the plane's, which troupe config cannot change, so the translation gives a key error a next_step of its own, the plane's administrator, and Troupe.UI.ModelError prefers it: the screen still branches on nothing. The root window of a session whose profile the client knows is named for it (spawned /build, not /root), as the window the worker opens before any event already was; a question or approval asked again under the same call id, as a call re-run after a restart asks it, replaces the one pending instead of being drawn twice; and /todo complete <n> sends the complete that todo.edit has always taken. Proof: test/troupe/cli_test.exs, the translation, model-config, recorded-question and recorded-approval tests, and worker_commands_test.exs.

Governs: clients/tui/lib/troupe/remote/worker.ex